Article Sections
Analysis of machined electron beam treated Ti6Al4V-ELI implant surfaces
Loading author information...
Graphical Abstract & Abstract

This work contributes to the problem of individual replacements of human joints by applying new types of implants and materials, made using modern additive technologies (melting of metal powders by laser and electron beam). The main attention is paid to the method called Electron Beam Melting used with the ARCAM Q10plus machine. Analyses of the sintered Ti6Al4V - ELI alloy samples were made from the point of view of production precision and quality after sintering in different technological modes and the surface quality reached after turning and tumbling, including measurement of other physical quantities. The results confirm an important effect of sample inclination in the chamber when building on the precision of the shape and quality of the surface. The tensile strengths were high (up to 1,012 MPa) and statistically consistent. Furthermore, the material exhibited high resistance to machining, expressed in terms of force loading and specific cutting forces, measured for a range of fe
How to Cite
(2019). Analysis of machined electron beam treated Ti6Al4V-ELI implant surfaces. Advanced Materials Letters, 10(6), 381-385. https://doi.org/10.5185/amlett.2019.2229