Graphical abstract for Quantitative Detect of Fatigue of Membrane of Erythrocyte in Uniform Shear Field

An erythrocyte has high deformability. In the shear field, it deforms from biconcave disc to ellipsoid, and make tank-treading motion at the membrane. When the membrane is ruptured by fatigue, contents get out from the inside of the cell (hemolysis). At the fatigue test of the membrane in the shear field, “the shear stress” as “the amplitude” and “the shear rate” × “the exposure time” as “repeat count” are critical parameters. For the quantitative fatigue test, the uniform shear field has been realized between the rotating concave cone and the stationary convex cone. With the rheoscope, deformability is evaluated with shear stress responsiveness and with critical deformation calculated from an exponential curve between the deformation ratio (the ratio between the major axis and the minor axis of the ellipsoidal shape) and the shear stress. Deformability decreases at erythrocytes of high density after shearing. The erythrocytes deformation ratio varies periodically at the double frequen

How to Cite

(2020). Quantitative Detect of Fatigue of Membrane of Erythrocyte in Uniform Shear Field. Advanced Materials Letters, 11(3), 1-5. https://doi.org/10.5185/amlett.2020.031485